Research on SVG DC-Side Voltage Control Based-on PSO Algorithm

Full Text (PDF, 621KB), PP.29-38

Views: 0 Downloads: 0

Author(s)

Yingwei Xiao 1,*

1. School of Electrical Engineering and Automation, Hefei University of Technology, Hefei, 230009, china

* Corresponding author.

DOI: https://doi.org/10.5815/ijitcs.2016.10.04

Received: 20 Jan. 2016 / Revised: 23 May 2016 / Accepted: 11 Aug. 2016 / Published: 8 Oct. 2016

Index Terms

SVG, DC voltage stability control, PSO, off-line PSO-PI, online PSO-PI

Abstract

The operation flow of particle swarm optimization (PSO) is presented, at the same time the PSO algorithm and GA algorithm are used to find the optimal value of the standard function, simulation results show that the PSO algorithm has better global search performance and faster search efficiency. The inertia weight decreasing strategy of PSO algorithm is studied, the simulation results show that the concave function decreasing strategy can accelerate the convergence rate of the algorithm. The stability control of the DC-side voltage is very important for the static var generator (SVG) compensation, but the disadvantages of the traditional PI control are fixed parameters and poor adaptability of dynamic response, PSO algorithm is introduced to the optimization of PI parameters, so online PSO-PI control and off-line PSO-PI control are obtained, the SVG voltage loop transfer function is used as the controlled object. The simulation results show that the PSO-PI control can satisfy the time varying system of the controlled object with strong adaptability.

Cite This Paper

Yingwei Xiao, "Research on SVG DC-Side Voltage Control Based-on PSO Algorithm", International Journal of Information Technology and Computer Science(IJITCS), Vol.8, No.10, pp.29-38, 2016. DOI:10.5815/ijitcs.2016.10.04

Reference

[1]Jie Tang, An Luo, Ke Zhou, “Design and Realization Voltage Control for Static Synchronous Compensator,” Transactions of China Electrotechnical Society, vol.21, no.8, pp.103-106, Aug.2006.

[2]Qing Lu, Wei Ni, Xiaohui Wang, Liyun Zhuang, “Study on SVG for reactive power compensation and harmonic suppression based on active current separation,” Control and Decision Conference (CCDC), Chinese, p. 3653-3657 2011.

[3]Hanson D.J., Woodhouse M.L., Horwill C., Monkhouse D.R., Osborne M.M., “STATCOM: a new era of reactive compensation,” Power Engineering Journal, vol.16, no.3, pp.151-160, Mar.2002.

[4]MingFeng Yeh, MinShyang Leu, KaiMin Chen, “Design of PID Controller Using Hybrid Particle Swarm Optimization,” Fuzzy Theory and it’s Applications, International Conference, Taichung, p. 333-337, 2012.

[5]Liqing Xiao, Chengchun Han, Xiaoju Xu, Weiyong Huang, “Hybrid Genetic Algorithm and Application to PID Controllers,” Chinese Control and Decision Conference, Xuzhou, p. 586-590, 2010.

[6]Neath M.J., Swain A.K., Madawala U.K., Thrimawithana D.J, “An Optimal PID Controller for a Bidirectional Inductive Power Transfer System Using Multi-objective Genetic Algorithm,” IEEE Transactions on Power Electronics, vol.29, no.3, pp.1523-1531, Mar.2014.

[7]Ali Shahcheraghi, Farzin Piltan, Masoud Mokhtar, Omid Avatefipour, Alireza Khalilian, “Design a Novel SISO Off-line Tuning of Modified PID Fuzzy Sliding Mode Controller,” I.J. Information Technology and Computer Science, vol.6, no.2, pp.72-83, Feb.2014.

[8]ZweLee Gaing, “A particle swarm optimization approach for optimum design of PID controller in AVR system,” IEEE Transactions on Energy Conversion, vol.19, no.2, pp.384-391, Feb.2004.

[9]Wael M. Elmamlouk, Hossam E. Mostafa, Metwally A. El-Sharkawy, “PSO-Based PI Controller for Shunt APF in Distribution Network of Multi Harmonic Sources,” I.J. Intelligent Systems and Applications, vol.5, no.8, pp.54-66, Aug.2013.

[10]Carlos A. Coello Coello, Gregorio Toscano Pulido, Maximino Salazar Lechuga, “Handling Multiple Objectives With Particle Swarm Optimization,” IEEE Transactions on Evolutionary Computation, vol.8, no.3, pp.256-279, Mar.2004.

[11]Adel T., Abdelkader C., “A Particle Swarm Optimization Approach for Optimum Design of PID Controller for nonlinear systems,” Electrical Engineering and Software Applications, International Conference, Hammamet, p.1-4, 2013.

[12]Aziz M.A.A., Taib M.N., Adnan R., “The Effect of Varying Inertia Weight on Particle Swarm Optimization(PSO) Algorithm in Optimizing PD Controller of Temperature Control System,” Signal Processing and its Applications, IEEE 8th International Colloquium, Melaka, p. 545-547, 2012.

[13]Jalilvand A., Kimiyaghalam A., Ashouri A., Mahdavi M., “Advanced Particle Swarm Optimization-Based PID Controller Parameters Tuning,” Multitopic Conference, IEEE International Conference, Karachi, p. 429-435, 2008.

[14]Khandani K., Jalali A.A., Alipoor M., “Particle Swarm  

Optimization based design of disturbance rejection PID controller for time delay systems,” Intelligent Computing and Intelligent Systems, IEEE International Conference, Shanghai, p. 862-866, 2009.

[15]Jianhong Qi,Jinda Cai, “Error Modeling and Compensation of 3D Scanning Robot System Based on PSO-RBFNN,” International Journal on Smart Sensing and Intelligent Systems, vol.7, no.2, pp.837-855, Feb.2014.

[16]RongJong Wai, JengDao Lee, KunLun Chuang, “Real-Time PID Control Strategy for Maglev Transportation System via Particle Swarm Optimization,” IEEE Transactions on Industrial Electronics, vol.58, no.2, pp.629-646, Feb.2011.

[17]Zakiah Mohd Yusoff, Zuraida Muhammad, Mohd Hezri Fazalul Rahiman, Mohd Nasir Taib, “Real Time Steam Temperature Regulation Using Self-tuning Fuzzy PID Controller on Hydro-diffusion Essential Oil Extraction System,” International Journal on Smart Sensing and Intelligent System, vol.6, no.5, pp.2055-2073, June,2013.

[18]Hidayat, Sasongko, P.H, Sarjiya, Suharyanto, “Performance Analysis of Hybrid PID-ANFIS for Speed Control of Brushless DC Motor Base on Identification Model System,” International Journal of Computer and Information Technology, vol.2, no.3, pp.694-700, Mar.2013.

[19]Xiaobin Zhang, Yanru Zhong, “Optimal Dynamic Hierarchical Control of the STATCOM DC Side Voltage,” Proceedings of the CSEE, vol.29, no.33, pp.60-67, Nov.2009.

[20]Qiaopo Xiong, An Luo, Xiao Wang, Xiaocong Li, Fujun Ma, Huagen Xiao, “DC Side Voltage Stability Analysis of Cascaded Static var Generator,” Automation of Electric Power Systems, vol.38, no.3, pp.25-29, Mar.2014.

[21]Hanxiang Cheng, Xianggen Yin, ZhiHua Wang, “Operation analysis of dual three-point SVG,” Proceedings of the 12th IEEE Mediterranean, Electrotechnical Conference, MELECON, vol.3, p.1141-1144, 2004.

[22]Li M., Chiasson J.N., Tolbert L.M., “Capacitor Voltage Control in a Cascaded Multilevel Inverter as a Static Var Generator,” CES/IEEE 5th International Conference on Power Electronics and Motion Control, 2006, IPEMC, vol.3, p.1-5, 2006.

[23]Gang Yao, Luan He, Xin Wang, LiDan Zhou, HuaJun Yu, “The study of hybrid modulation based on cascade SVG and its DC control method,” 2015 IEEE 28th Canadian Conference on Electrical and Computer Engineering (CCECE), p. 680-685, 2015.

[24]Kusic G.L., Whyte I.A., “Three Phase, Steady-State Static var Generator Filter Design for Power Systems,” IEEE Transactions on Power Apparatus and Systems, PAS-103(4), pp.811-818, Apr.1984.

[25]Dixon J., Moran L., Rodriguez J., “Domke R. Reactive Power Compensation Technologies: State-of-the-Art Review,” Proceedings of the IEEE, vol.93, no.12, pp2144-2164, Dec.2005.

[26]Xiaobin Zhang, Yanru Zhong, “Research on the mathematical model and DC-voltage of static var generator,” 4th IEEE Conference on Industrial Electronics and Applications, 2009, ICIEA, p.3292-3297, 2009.

[27]Guopeng Zhao, Jinjun Liu, Xin Yang, Weiwei Gan, Zhaoan Wang, “Analysis and specification of DC side voltage in Static var Generator regarding compensation characteristics of generators,” Applied Power Electronics Conference and Exposition, 2008, APEC 2008, Twenty-Third Annual IEEE, p.1235-1239, 2008.

[28]Zhang Z., Fahmi N.R., “Modeling and analysis of a cascade 11-level inverters-based SVG with control strategies for electric arc furnace (EAF) application,” IEE Proceedings, Generation, Transmission and Distribution, vol.150, no.2, pp.217-223, Feb.2003.

[29]Xiaobin Zhang, Yanru Zhong, “Dynamic Model and Nonlinear Inverse System-PI Control Strategy of Static Var Generator,” Journal of System Simulation, vol.21, no.11, pp. 3166-3170, Nov.2009.

[30]Guopeng Zhao, Minxiao Han, “Analysis of significant current tracking error and suppression of over-shoot current in grid-connected voltage source converter with abc frame control,” Power Electronics, IET, vol.7, no.9, pp. 2347-2353, Sep.2014.

[31]Yoshida H., Fukuyama Y., Takayama S., Nakanishi Y., “A Particle Swarm Optimization for Reactive Power and Voltage Control in Electric Power Systems Considering Voltage Security Assessment,” Systems Man and Cybernetics, IEEE International Conference, Tokyo, vol.6, p.497-502, 1999.

[32]Kiyong Kim, Rao P., Burnworth J.A., “Self-Tuning of the PID Controller for a Digital Excitation Control System,” IEEE Transactions on Industry Applications, vol.46, no.4, pp. 1518-1524, Apr.2010.

[33]Keyu Li, “PID Tuning for Optimal Closed-Loop Performance with Specified Gain and Phase Margins,” IEEE Transactions on Control Systems Technology, vol.23, no.3, pp. 1024-1030, Mar.2013.

[34]XingJian Jing, Li Cheng, “An Optimal PID Control Algorithm for Training Feedforward Neural Networks,” IEEE Transactions on Industrial Electronics, vol.60, no.6, pp. 2273-2283, Jun.2013.

[35]Benxian Xiao, Jun Xiao, Rongbao Chen, “PID Controller Parameters Tuning Based-on Satisfaction for Superheated Steam Temperature of Power Station Boiler,” I.J. Information Technology and Computer Science, vol.6, no.7, pp. 9-14, Jul.2014.

[36]Farahani, M., Ganjefar, S., Alizadeh, M., “PID controller adjustment using chaotic optimisation algorithm for multi-area load frequency control,” IET Control Theory & Applications, vol.6, no.13, pp. 1984-1992, Jul.2012.